HV 2 - vibration motor

Downloads & Documentation

HV 2

electric vibrators, standard execution

Threephase Vibration Motor

The sturdy housing is manufactured from aluminium chill casting. The amply dimensioned bearings are lubricated for life. The centrifugal force can be changed stepwise by taking off the eccentric weights. The vibrator can be run continously with all the eccentric weights mounted, under consideration of the admissible power consumption.

Standard voltage: 230/400 vs. 50 cps. Other voltages are available.

* These bipolar units are also available as extra executions of 230 vs., 50 cps.A.C. For this, an operation capacitor of 7µF can be delivered.

Type of protection IP 65 · Insulant class F
All HV 2 rotary current units can be delivered also in protection class ATEX II 2G/D EEx e II T3 See HVE 2

Overview

Line Model Synchr. speed Centrifugal force Workingmoment Centrifugal forcesettings Stand. voltage Nominal current Power input Offering
min.-1 N cm kg Number of slices 50 Hz / V A P1, W
1 HV 2/2* 3000 880 1,85 in stages 4 3 ~ 230/400 0,49/0,29 160 Request
2 HV 2/2-2* 3000 1320 2,8 in stages 6 3 ~ 230/400 0,49/0,29 160 Request
3 HV 2/2-4* 3000 1760 3,7 in stages 8 3 ~ 230/400 0,49/0,29 160 Request
4 HV 2/2-6* 3000 2860 6 in stages 13 3 ~ 230/400 0,49/0,29 160 Request
5 HV 2/4 1500 220 1,85 in stages 4 3 ~ 230/400 0,57/0,33 140 Request
6 HV 2/4-2 1500 330 2,8 in stages 6 3 ~ 230/400 0,57/0,33 140 Request
7 HV 2/4-4 1500 440 3,7 in stages 8 3 ~ 230/400 0,57/0,33 140 Request
8 HV 2/4-6 1500 715 6 in stages 13 3 ~ 230/400 0,57/0,33 140 Request
9 HV 2/4-9 1500 1100 9 in stages 20 3 ~ 230/400 0,57/0,33 140 Request

Dimensions

Model Bores for fastening1 Base measurements (mm) Outside measurements (mm) Mass
a b Øs c e f h g p k kg
HV 2/· 65 140 13 25 157 162 80 96 128 189 5,2
HV 2/·-2 80 110 11 25 157 162 80 96 128 201 5,5
HV 2/·-4 115 135 11 25 157 162 80 96 128 215 6,0
HV 2/·-6 135 115 11 25 157 162 80 96 128 250 6,7
HV 2/4-9 124 110 11 25 157 162 80 96 128 283 7,7

1 All mentioned fastening holes are provided in the unit.