HV 6 D

Vibration motors, standard execution

Threephase Vibration Motor

The sturdy housing is manufactured from aluminium chill casting. The amply dimensioned bearings 6303 2Z C4 are lubricated for life. The centrifugal force can be changed by means of mountable eccentric weights. The vibrator can be run continously with all the eccentric weights mounted, under consideration of the admissible power input. (*exeption: type HV 6/2-8 with 40% connection time)

Standard voltage: 230/400 vs. 50 cps. Other voltages are available.

Type of protection IP 65 · Insulant class F

All HV 6 rotary current units can be delivered also in protection class ATEX II 3G/D T3. See HVe 6

Overview

Line Model Synchr. speed Centrifugal force Workingmoment Centrifugal forcesettings Stand. voltage Nominal current Power input Offering
min.-1 daN cm kg Number of slices per page 50 Hz / V A P1, W
1 HV 6/2 3000 305 6,1 in stages 8 3 ~ 230/400 0,99/0,57 300 Request
2 HV 6/2-8* 3000 420 8,4 in stages 11 3 ~ 230/400 0,99/0,57 300 Request
3 HV 6/4-11 1500 143 11,5 in stages 15 3 ~ 230/400 0,75/0,43 190 Request
4 HV 6/4-18 1500 220 17,8 in stages 23 3 ~ 230/400 0,75/0,43 190 Request
5 HV 6/6 1000 34 6,1 in stages 8 3 ~ 230/400 0,78/0,45 150 Request
6 HV 6/6-18 1000 98 17,8 in stages 23 3 ~ 230/400 0,78/0,45 150 Request
7 HV 6/8 750 19 6,1 in stages 8 3 ~ 230/400 0,54/0,31 120 Request
8 HV 6/8-18 750 55 17,8 in stages 23 3 ~ 230/400 0,54/0,31 120 Request

Dimensions

Model Bores for fastening1 Base measurements (mm) Outside measurements (mm) Mass
a b Øs c e f h g p k kg
HV 6/2 65 140 13 25 157 162 86 114 144 230 7,5
HV 6/2-8 80 110 11 25 157 162 86 114 144 270 8,7
HV 6/4-11 (115 135 11) 25 157 162 86 114 144 270 9,0
HV 6/4-18 135 115 11 25 157 162 86 114 144 320 11,0
HV 6/ · 124 110 11 25 157 162 86 114 144 230 8,0
HV 6/ · -18 25 157 162 86 114 144 320 11,5

1 All mentioned fastening holes are provided in the unit.






HV 6 H

Vario fastening hole H 80 x 175

The sturdy housing is manufactured from aluminium chill casting. The amply dimensioned bearings 6303 2Z C4 are lubricated for life. The centrifugal force can be changed by means of mountable eccentric weights. The vibrator can be run continously with all the eccentric weights mounted, under consideration of the admissible power input. (*exeption: type HV 6/2-8 with 40% connection time)

Standard voltage: 230/400 vs. 50 cps. Other voltages are available.

Type of protection IP 65 · Insulant class F

All HV 6 rotary current units can be delivered also in protection class ATEX II 3G/D T3. See HVe 6

Overview

Line Model Synchr. speed Centrifugal force Workingmoment Centrifugal forcesettings Stand. voltage Nominal current Power input Offering
min.-1 daN cm kg Number of slices per page 50 Hz / V A P1, W
1 HV 6/2H 3000 305 6,1 in stages 8 3 ~ 230/400 0,99/0,57 300 Request
2 HV 6/4-18H 1500 220 17,8 in stages 23 3 ~ 230/400 0,75/0,43 190 Request

Dimensions

Model Bores for fastening Base measurements (mm) Outside measurements (mm) Mass
a b Øs c e f h g p k kg
HV 6/2H 80 175 13 25 115 205 86 114 144 230 7,5
HV 6/4-18H 80 175 13 25 115 205 86 114 144 320 11,0